Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Resonance Frequency' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Resonance Frequency' found in 1 term [] and 13 definitions [], (+ 13 Boolean[] results
previous     11 - 15 (of 27)     next
Result Pages : [1]  [2 3]  [4 5 6]
Searchterm 'Resonance Frequency' was also found in the following services: 
spacer
News  (5)  Resources  (2)  
 
Multiply Tuned CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
RF coil designed to operate at more than one resonance frequency, so that NMR of more than one kind of nucleus can be observed with the same coil.
spacer
MRI Resources 
Absorption and Emission - Open Directory Project - Pediatric and Fetal MRI - Spine MRI - Shoulder MRI - MRI Reimbursement
 
Nuclear Magnetic ResonanceMRI Resource Directory:
 - NMR -
 
(NMR) Nuclear Magnetic Resonance is a physical phenomenon of the magnetic property of nuclei, which have a positive nuclear spin quantum number.
Under the influence of an external static magnetic field this nuclei will precess about the direction of the magnetic field with an angular frequency (Larmor frequency). Through absorption and emission of RF energy (gradients, RF coils) at the resonance frequency (Larmor equation) and the processing of this raw data by the Fourier transformation - physical, chemical, electronic, and structural information about molecules can be obtained (NMR Magnetic Resonance Spectroscopy, Magnetic Resonance Imaging).
spacer

• View the DATABASE results for 'Nuclear Magnetic Resonance' (11).Open this link in a new window


• View the NEWS results for 'Nuclear Magnetic Resonance' (1).Open this link in a new window.
 
Further Reading:
  Basics:
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
Nuclear magnetic resonance with no magnets
Wednesday, 18 May 2011   by www.physorg.com    
  News & More:
Neuromelanin-Sensitive MRI Identified as a Potential Biomarker for Psychosis
Sunday, 10 February 2019   by www.nimh.nih.gov    
A powder to enhance NMR signals
Thursday, 12 December 2013   by phys.org    
New Paradigm for Nanoscale Resolution MRI Experimentally Achieved
Friday, 27 September 2013   by www.sciencedaily.com    
MRI Resources 
Absorption and Emission - Education - General - Musculoskeletal and Joint MRI - Functional MRI - Safety Products
 
Radio FrequencyForum -
related threads
 
(RF) Radio frequency refers to that portion of the electromagnetic spectrum in which electromagnetic waves can be generated by alternating current fed to an antenna.
The RF pulses used in MRI are commonly in the 1-100 megahertz range, and their effect upon a body is potential heating of tissues and foreign bodies, such as metallic implants, mainly at the surface.
This is a principal area of concern for MRI safety limits caused by absorption (see specific absorption rate) of the applied pulses of RF energy.
mri safety guidance
Image Guidance
The higher the frequency, the larger will be the amount of heat developed.
The more ionic the biochemical environment in the tissue, the more energy that will be deposited as heat.
This effect is well known for homogeneous model systems, but the complex structure of various human tissues makes detailed theoretical calculations very difficult, if not impossible. By scanning problems, it is important to verify the transmission frequency. If the RF transmitted into the patient was, e.g. 5000 Hz lower than the resonance frequency of the protons, no protons was excited, and no signal returns.
spacer

• View the DATABASE results for 'Radio Frequency' (72).Open this link in a new window


• View the NEWS results for 'Radio Frequency' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Radio frequency
   by en.wikipedia.org    
  News & More:
On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI.
Thursday, 2 March 2017   by www.ncbi.nlm.nih.gov    
Safety and reliability of Radio Frequency Identification Devices in Magnetic Resonance Imaging and Computed Tomography
Thursday, 4 February 2010   by 7thspace.com    
Radiologists Offer Non-surgical Treatment For Early-stage Liver Cancer
Saturday, 5 March 2005   by www.sciencedaily.com    
Searchterm 'Resonance Frequency' was also found in the following services: 
spacer
News  (5)  Resources  (2)  
 
Shift Reagents
 
Paramagnetic compounds designed to induce a shift in the resonance frequency of nuclei with which they interact. For example, many rare earth's have been used as shift reagents for positive metal ions such as sodium and potassium.
spacer
MRI Resources 
Developers - Universities - Open Directory Project - Supplies - Absorption and Emission - Jobs pool
 
MRI History
 
•
Sir Joseph Larmor (1857-1942) developed the equation that the angular frequency of precession of the nuclear spins being proportional to the strength of the magnetic field. [Larmor relationship]
•
In the 1930's, Isidor Isaac Rabi (Columbia University) succeeded in detecting and measuring single states of rotation of atoms and molecules, and in determining the mechanical and magnetic moments of the nuclei.
•
Felix Bloch (Stanford University) and Edward Purcell (Harvard University) developed instruments, which could measure the magnetic resonance in bulk material such as liquids and solids. (Both honored with the Nobel Prize for Physics in 1952.) [The birth of the NMR spectroscopy]
•
In the early 70's, Raymond Damadian (State University of New York) demonstrated with his NMR device, that there are different T1 relaxation times between normal and abnormal tissues of the same type, as well as between different types of normal tissues.
•
In 1973, Paul Lauterbur (State University of New York) described a new imaging technique that he termed Zeugmatography. By utilizing gradients in the magnetic field, this technique was able to produce a two-dimensional image (back-projection). (Through analysis of the characteristics of the emitted radio waves, their origin could be determined.) Peter Mansfield further developed the utilization of gradients in the magnetic field and the mathematically analysis of these signals for a more useful imaging technique. (Paul C Lauterbur and Peter Mansfield were awarded with the 2003 Nobel Prize in Medicine.)
•
In 1975, Richard Ernst introduced 2D NMR using phase and frequency encoding, and the Fourier Transform. Instead of Paul Lauterbur's back-projection, he timely switched magnetic field gradients ('NMR Fourier Zeugmatography'). [This basic reconstruction method is the basis of current MRI techniques.]
•
1977/78: First images could be presented. A cross section through a finger by Peter Mansfield and Andrew A. Maudsley. Peter Mansfield also could present the first image through the abdomen.
•
In 1977, Raymond Damadian completed (after 7 years) the first MR scanner (Indomitable). In 1978, he founded the FONAR Corporation, which manufactured the first commercial MRI scanner in 1980. Fonar went public in 1981.
•
1981: Schering submitted a patent application for Gd-DTPA dimeglumine.
•
1982: The first 'magnetization-transfer' imaging by Robert N. Muller.
•
In 1983, Toshiba obtained approval from the Ministry of Health and Welfare in Japan for the first commercial MRI system.
•
In 1984, FONAR Corporation receives FDA approval for its first MRI scanner.
•
1986: Jürgen Hennig, A. Nauerth, and Hartmut Friedburg (University of Freiburg) introduced RARE (rapid acquisition with relaxation enhancement) imaging. Axel Haase, Jens Frahm, Dieter Matthaei, Wolfgang Haenicke, and Dietmar K. Merboldt (Max-Planck-Institute, Göttingen) developed the FLASH (fast low angle shot) sequence.
•
1988: Schering's MAGNEVIST gets its first approval by the FDA.
•
In 1991, fMRI was developed independently by the University of Minnesota's Center for Magnetic Resonance Research (CMRR) and Massachusetts General Hospital's (MGH) MR Center.
•
From 1992 to 1997 Fonar was paid for the infringement of it's patents from 'nearly every one of its competitors in the MRI industry including giant multi-nationals as Toshiba, Siemens, Shimadzu, Philips and GE'.
•
 
Images, Movies, Sliders:
 Cardiac Infarct Short Axis Cine Overview  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 
spacer

• View the DATABASE results for 'MRI History' (6).Open this link in a new window


• View the NEWS results for 'MRI History' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Magnetic Resonance Imaging, History & Introduction
2000   by www.cis.rit.edu    
A Short History of the Magnetic Resonance Imaging (MRI)
   by www.teslasociety.com    
Fonar Our History
   by www.fonar.com    
  News & More:
Scientists win Nobels for work on MRI
Tuesday, 10 June 2003   by usatoday30.usatoday.com    
2001 Lemelson-MIT Lifetime Achievement Award Winner
   by web.mit.edu    
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
MRI Resources 
Coils - Spectroscopy pool - Databases - MRI Physics - Patient Information - Nerve Stimulator
 
previous      11 - 15 (of 27)     next
Result Pages : [1]  [2 3]  [4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 1 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]